Comparative Study of MR 3D-SPACE, 3D-True FISP Sequences at Articular Cartilage of Knee Joint
Author:CHEN Hao, ZHUANG Qi-xiang, SUN Yan,et al.
affiliation:Department of Radiology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou 215008, Jiangsu Province, China
PDFAbstract
Objective To compare the diagnostic value via imaging quality of the articular cartilage of knee with the 3D-SPACE, 3D-True FISP sequences. Methods Before treated by arthroscope in the next week., 43 patients of knee joint were examined with 3D-SPACE and 3D-True FISP sequences at 1.5T MRI .Lesion visualization of articular cartilage were compared. Results 3D-SPACE comparing with 3D-True FISP not only finding more numbers of cartilage injury, but also having significant difference between the cartilage injury at level Ⅰ and level Ⅱ(P<0.05). Conclusions Compared with the 3D-True FISP sequence 3D-SPACE sequence can show the knee cartilage injury better.
【Keyword】MRI; Articular Cartilage of Knee; 3D-SPACE Sequence; 3D-True FISP Sequence
【Chart number】R445.2
【Document Identification Number】A
【DOI】10.3969/j.issn.1009-3257.2016.05.021
Journal of Rare Diseases
th23Volume, th 6 Issue
2019Year11Month
Related articles