论著-头颈部
16排螺旋CT与320排容积CT对颈动脉粥样硬化斑块检出率的比较研究
作者:贾云生1 高明洋1 王焕君2
所属单位:1.河北省沧县医院影像科 (河北 沧州 061009) 2.河北省沧州市中心医院神经内科 (河北 沧州 061014)
PDF摘要
目的 比较16排螺旋CT与320排容 积CT对于颈动脉粥样硬化斑块检出率的差 异。方法 选取缺血性脑血管病患者48例, 男性22例,女性26例,平均年龄(56±8) 岁。经16排螺旋CTA检出颈动脉粥样硬化 斑块的患者,进一步行320排容积CTA扫 描,并与16排螺旋CTA的粥样硬化斑块检 出率进行比较。结果 16排螺旋CT与320排 容积CT对于颈动脉粥样硬化斑块的检出 率无明显统计学差异。结论 对于基层医 院,建议使用16排螺旋CT检出颈动脉斑 块,以利于临床诊断及治疗。
Objective To compare the detection rate of carotid artery therosclerosis plaque by means of 16-director spiral CT and 320- director volume CT. Methods 48 patients of ICVD, 22 males and 26 females, with average age of (56±8) years old, were chosen. The patients detected plaques by 16-director spiral CT scans were further performed 320- director volume CT scans, and we compared the detection rate between the two methods. Results The detection rate of carotid artery therosclerosis plaque between 16-director spiral CT scans and 320-director volume CT scans showed no significant difference. Conclusion We recommend utilizing 16-director spiral CT to detect carotid artery therosclerosis plaque for basic hospital, facilitating the clinical diagnosis and treatment
【关键词】16排螺旋CT;320排容积CT; 颈动脉;粥样硬化斑块
【中图分类号】R826.62
【文献标识码】A
【DOI】 10.3969/j.issn.1672- 5131.2016.07.008
前言
对颈动脉粥样硬化斑块采取有效可靠的检测方法,对于早期发 现、早期治疗颈动脉粥样硬化斑块意义重大。以往文献报道多层螺旋 CT检测颈动脉粥样硬化斑块效果显著。但我国基层医院均已拥有16排 CT扫描机,但尚未普及64排或320排CT扫描机。本研究对比16排螺旋CT 扫描机与320排容积CT扫描机对于颈动脉斑块检出率,对广大基层医院 应用16排CT扫描机进行劲动脉斑块成像的可行性进行论证。
中国CT和MRI杂志
第14卷, 第 7 期
2016年07月
相关文章