Head and Neck Imaging
Applied PET-CT for Determine the Target of CT-guided Biopsies for the Patients with Spinal Lesions*
Author:ZHAO Qin-peng, ZHANG Zheng-ping, ZHANG Hai-ping, et al.
affiliation:Department of Spinal Surgery, Xi'an Hong-Hui Hospital, Xi'an Jiaotong University College of Medical. Xi'an 710054, China
PDFAbstract
Objective To determine the accuracy of CT-guided spinal biopsy benefitted from PET-CT, to compare the results with those without PET-CT, and to determine if PET-CT influence the accuracy of CT-guided thoracic spinal biopsy. Methods In total, 180 consecutive CT-guided percutaneous thoracolumbar spine procedures (performed at the Department of Spinal Surgery, Xi'an Red Cross Hospital between April 2000 and July 2014) were reviewed. The 180 lesions were categorized by CT or MRI. Pathological and clinical follow-up were used to determine accuracy. Results The diagnostic accuracy of CT-guided spinal biopsy was 93.5% overall. CT-guided spinal biopsy benefitted from PET-CT (98.62%) was significantly more accurate than biopsies of general (90.12%) (P <0.05 ). Conclusion Percutaneous CT-guided spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was improved by PET-CT.
【Keyword】Spine; CT; Biopsy
【Chart number】R681.5;R445.3
【Document Identification Number】A
【DOI】10.3969/j.issn.1672-5131.2015.09.002
Chinese journal of CT and MRI
th13Volume, th 9 Issue
2015Year09Month
Related articles