不同病理类型肺癌 的双源CT参数特征 及诊断鉴别价值
作者:刘 洋1 寻 航1 李修奎1 姚鹏飞2
所属单位:1.山东省临沂市肿瘤医院影像科 (山东 临沂 276001) 2.山东省临沂市临沐县人民医院影 像科 (山东 临沂 276700)
PDF摘要
目的 探讨不同病理类型肺癌 的双源CT双能量参数特征及诊断鉴别价 值。方法 以我院86例初诊肺癌患者均 接受双源CT双能量成像系统检测,其中 腺癌52例,鳞癌34例,扫描后分析鳞 癌、腺癌患者各期CT净增值和时间-密 度曲线,比较两组差异。结果 肺腺癌 主动脉达峰时间(21.04±0.23)s,肺 鳞癌(23.12±0.3)s,差异具有统计学 意义(P<0.05);增强扫描各期CT净增 值比较,腺癌组在达峰时、达峰后第 60s、第100s显著高于鳞癌组,差异具 有统计学意义(P<0.05);两组达峰后第 40s差异不具有统计学意义(P>0.05); 肺腺癌增强扫描CT净增值在主动脉达 峰时最低(P<0.05),在第40s显著上升 (P<0.05),后随着时间推移呈逐渐上升 趋势;鳞癌CT净增值在主动脉达峰时最 低(P<0.05),在第40s达到最高点,在 第40-60s略有降低,第60-100s呈平台 期。结论 腺癌CT净增值时间-密度曲线 具有逐渐上升趋势特点,而鳞癌时间— 密度曲线具有先上升,后降低,再平缓 趋势,双源CT双能量成像可为腺癌、鳞 癌病理学诊断提供一定参考依据。
Objective To explore the dual-source CT dual-energy parameters and their value in differential diagnosis value of different pathological types of lung cancer. Methods A total of 86 cases of newly diagnosed lung cancer patients admitted to our hospital during November 2014-November 2016 were examined with dual-source CT dual -energy imaging, including 52 cases of adenocarcinomas and 34 cases of squamous cell carcinomas. After scanning, the CT net added values and time-density curve of patients with squamous cell carcinoma and adenocarcinoma in different phases were analyzed and compared. Results The time to peak of lung adenocarcinoma was (21.04±0.23)s, while of lung squamous cell carcinoma was (23.12±0.3)s (P<0.05). The CT net added values of enhanced scan in different phases in adenocarcinoma group to peak, 60s and 100s after reaching the peak were significantly higher than those of the squamous cell carcinoma group (P<0.05). There was no significant difference between the two groups at 40s after reaching the peak (P>0.05). The CT net added value of enhanced scan for lung adenocarcinoma was the lowest in aortic peak, it increased significantlyat the 40thsecond (P<0.05) and increased gradually over time. The CT net added value of squamous cell carcinoma was the lowest in aortic peak(P<0.05), it was the highest at the 40thsecond, slightly decreased at the 40th-60thsecond, and it was in platform stage in 60th100thsecond. Conclusion The time-density curve of adenocarcinoma CT net added value shows a gradually increasing trend while that of squamous cell carcinoma shows an firstly increasing, then decreasing and finally flat trend. Dual-source CT dual energy imaging can provide certain references for pathological diagnosis of adenocarcinoma and squamous cell carcinoma.
【关键词】肺癌;双源CT双能量成像; 鉴别价值
【中图分类号】R734.2;R445.3
【文献标识码】A
【DOI】 10.3969/j.issn.1672- 5131.2018.02.023
前言
肺癌为死亡率高居首位的恶性肿瘤,准确的临床病理分型有利于 指导个性化放化疗、手术方案的实施和预后判断[1-3]。病理学诊断为 肺癌临床分型金标准,但对于部分传统临床表现、病理学、遗传学等 手段无法准确判断的病理类型,仍需其他辅助方法鉴别诊断[4]。影像 学作为判断肺癌病理类型的重要手段,传统PET/CT、肺灌注成像可依 据患者形态学、增强扫描病灶等方式诊断肺癌类型,但PET/CT费用较 高,并且诊断阳性率偏高,而肺灌注成像辐射剂量大,均存在一定 缺陷[5]。双源CT双能量是近几年逐渐应用于病理诊断的新型CT设备, 可经一系列减少射线剂量的扫描方法,利用双能量碘图成像系统获得 癌灶增强扫描不同时间段净增加值,进而鉴别不同类型病理学特征癌 症[6]。本研究针对我院病理诊断为肺鳞癌、肺腺癌患者,采用双源CT 双能量成像系统进行鉴别诊断,为临床肺癌鉴别提供依据。具体报道 如下。
中国CT和MRI杂志
第16卷, 第 2 期
2018年02月
相关文章